Swing check valves are normally recommended for water and wastewater systems applications because of the simple construction, low pressure drop across the valve, and field serviceability. Swing check valves are available in either metal-to-metal seat or resilient seating. Resilient seated swing check valves are usually recommended for wastewater or services where dirt or other particles may be present in the fluid and positive shutoff is required. Typically a swing check valve operation depends on gravity (weight of disc) and reverse flow. The pivot point of the swing check is outside the periphery of the disc and, the greater the flow velocity and head pressure possibility the greater the valve closing force. To prevent the slamming of the disc and reducing hydraulic shocks external hinge arm is available with either a lever weight or an adjustable spring.
Size
2” (50 mm) to 12” (300 mm)
Class
150# / 300#
End Connection
Flanged End to ASME B16.5 RF
Design / Mfg. Std.
BS 1868 / API 6D
Face to face Std.
ASME B16.10 / API 6D
Inspection & Testing Std.
API 6D / API 598 / BS-EN 12266PI
*Special Material & Higher Size also available on request.